A purchasing guide to matching the CF-HQ190L scope with a processor and light source—and separating scope-only pricing from a system quote.
The Olympus CF-HQ190L is a video colonoscope. A scope-only listing does not supply the rest of the imaging system. Before ordering, identify equipment you already own and list the components you still need.
The documented original combination
| Component | Model | Purchase check |
|---|---|---|
| Video colonoscope | CF-HQ190L | Confirm individual condition and package. |
| Video system center | CV-190 | Confirm exact supplied configuration. |
| Xenon light source | CLV-190 | Confirm model and functional condition. |
The original Olympus brochure names the CV-190 and CLV-190. This is a documented combination, not a complete list of every platform Olympus may support. Ask for confirmation of your exact models and regional configuration rather than assuming universal compatibility.

What the current scope-only offer covers
Our Used & Tested CF-HQ190L listing includes the colonoscope only. No processor, light source, ScopeGuide hardware or additional accessories are included. Seller testing used a CV-190 and CLV-190; that test configuration does not change the supplied package.
Items to discuss for a complete system quote
- The specific processor and light source, including their condition and supplied components.
- Monitor and recording requirements, plus the connections needed for the agreed configuration.
- Required valves, adapters and other accessories, itemized rather than assumed.
- Any ScopeGuide equipment you require, separately identified and quoted.
- Destination, intended installation arrangements and who will verify the system before use.
Have a qualified technician verify the proposed combination and the applicable manufacturer instructions. This guide does not specify a clinical installation procedure.
Equipment already in your facility
Send model-label photos of the processor and light source with your inquiry. Include your monitor/recording requirements and any existing accessories you want to retain. Sales can then quote the missing components and identify compatibility questions before payment.
Do not substitute a generic series number for exact model identification. Also separate feature compatibility from evidence that the offered physical unit has passed a particular test.
Review separately sold equipment
These are separate listings. Confirm current prices, availability and the final matched-system package in writing; do not add unrelated listings together and assume that every required part is supplied.
Final verification before use
Before patient use, a certified biomedical technician must test the scope and verify its condition and functionality. Follow applicable Olympus reprocessing instructions and facility procedures. Seller checks do not establish readiness for patient use.
For condition evidence and commercial checks, use our used CF-HQ190L buying checklist.